2000.35.010 RFID CONVERTER RTD -4...20MA

Precedente
Successivo
2000.35.010

This temperature transmitter for DIN/B head converts a signal acquired via PT100, PT1000, Ni100 probes or thermocouple into a  current signal for 4..20mA loop (2-wire technology).

Unique features is the programming via NFC technology, not requiring the devices to be powered up. User can chose between a dedicated NFC programmer and RF-Programmer software on Pc or App MyPixsys on smartphone available on Play Store.

2000.35.010 RFID CONVERTER RTD -4..20MA RTD version

€55.51
Tax included

FEATURES

Dimensions Ø45 mm, 23mm
Power supply Loop Power (2 wires connection) operating range 6-32 Vdc
Operating conditions Temperature -40..85 °C, Humidity 30..90 RH%
Material Nylon (PA66)
Weight Approx. 30g
Response time 600mS (sampling 300mS)
Sealing Box and terminal blocks: IP20
According to CE, UL
Analog inputs 1 x selectable among Thermoresistances PT100, PT1000, Ni100 - 2/3/4 wires
Data Logger Function Sampling time 1..3600 S - 2800 damplings - circular buffer
Control algorithms ON - OFF with hysteresis, P., P.I., P.I.D., P.D. time proportional
Tuning Manual or automatic
Alarm mode Absolute / Threshold, Band, High / Low deviation. Alarm with optional Manual reset. Loop Break Alarm
Double P.I.D. Heating / Cooling with dual P.I.D.
Soft-Start Rising gradient programmable as Degree / Hour or fixed output %
Open/Close logics Open / Close logic for motorized valves
Software parameter configuration Memory Card, software LABSOFTVIEW, EASY-UP codes - Programming via APP (NFC) "MyPixsys" for Android and iOS devices
Rejection 50-60Hz
Output resolution 2 μA
Max. transmission error 0,1% f.s or 0,2°C
Cable resistance Max 20Ω
Over range output f.s. + 5°C
Under range output f.s. - 5°C
Error output Selectable between 21,5mA or 3,8mA
Current output protection 30mA