ATR264 is a programmer dedicated to the automation of small industrial ovens or laboratory ovens, dryers, heat treatment systems, and in general the management of a process involving cycles/profiles with control of the process variable in relation to time.
ATR264 allows the programming of 15 cycles/profiles, each one including up to 30 steps/segments, all free configurable by the user as ramp/soak/cooling.
The device integrates software functions typically required in oven/furnace management: Waiting (in the case the process is delayed in comparison to programmed setpoint) and Cycle Recovery mode (after any power failure). Special function for gas kilns management are available.
Like other Pixsys programmers, ATR264 stands out for user-friendly interface and programming mode even for inexperienced operators.
Parameter configuration and cycle programming is possible via MyPixsys App on smartphone thanks to NFC/Rfid technology or on PC with MyPixsysLab software as well as directly from keyboard.
ATR264-13ABC PROGRAMMER/TEMP. CONTR. 15 CYCLE 48X48 4+5 digit 1AI-1AO-2DI/O-3RELAYS
FEATURES
Dimensions | 48x48x80mm |
---|---|
Power supply | 24..230V AC/DC ±15% 50/60 Hz - galvanic isolation 2,5KV |
Consumption | 8 Watt/VA |
Operating conditions | Temperature 0..45 °C, humidity 35..95 RH% (non-condensing), max 2000m a.s.l. |
Front panel | 48 x 48mm |
Material | Box: PC UL94V2 self-extinguishing, front panel: PC UL94V2 |
Weight | Approx. 185g |
Sealing | Front panel: IP65, Box and terminal blocks: IP20 |
According to | CE |
Analog inputs | 1x 16bit, K,J,S,R,T,E,N,B (comp. -25..85°C, @25°±0,2% F.S. ±1 digit F.S.), PT100, PT500, PT1000, Ni100, PTC 1K, NTC 10K (B3435K), 0-20/4..20mA, 0-1/0-5/0-10V; 0..60mV, Potentiometers F.S. 1..150KΩ, Current transf. 50mA |
Digital outputs | 2 x PNP 12VDC - 25mA o 24VDC - 15mA selectable by parameter |
Relais outputs | 3 x 2A - 250V AC resistive loads |
Control algorithms | ON - OFF with hysteresis, P., P.I., P.I.D., P.D. time proportional |
Tuning | Manual or automatic |
Alarm mode | Absolute / Threshold, Band, High / Low deviation. Alarm with optional Manual reset. Loop Break Alarm |
Double P.I.D. | Heating / Cooling with dual P.I.D. |
Open/Close logics | Open / Close logic for motorized valves |
Software parameter configuration | Software MyPixsysLab, App MyPixsys |
Digital inputs | 2 x PNP |
Serial communication | RS485 (1200..115200 Baud) galvanically isolated |
Analogue outputs | 1 x 4..20mA (40000 points ± 0,2% F.S ) or 0..10VDC (40000 points ± 0,2% F.S.) |
Cycles / Profiles | up to 15 |
Steps / Segments | up to 30 for each cycle ( max duration per step 99.59 hh.mm) |